Battery chargers and DC systems support control, protection, emergency and auxiliary loads that must remain available when normal AC power is disturbed. SMEC engineers project-specific charger, battery and DC distribution packages around the required DC voltage, autonomy, battery chemistry, load profile, redundancy and alarm interfaces.
Specifications
- Nominal output voltage
- 12 / 24 / 48 V DC
- Total charge current
- 10 / 20 / 40 / 100 A
- Number of battery outlets
- 1 No.
- Battery capacity range
- 200 – 1000 Ah
- Nominal input voltage
- 110 / 230 / 415 V AC 50/60 Hz
- Input voltage range
- +10% / −10%
01Overview
About the Battery Charger
Specifications
- Nominal output voltage
- 12 / 24 / 48 V DC
- Total charge current
- 10 / 20 / 40 / 100 A
- Number of battery outlets
- 1 No.
- Battery capacity range
- 200 – 1000 Ah
- Nominal input voltage
- 110 / 230 / 415 V AC 50/60 Hz
- Input voltage range
- +10% / −10%
- Power supply mode
- Yes
- Display / read-out
- LED display
- Galvanic isolation
- Yes
- Weight
- 6 – 15 kg
- Charge characteristic
- 3 stage charger
- Charge current bulk
- 0 – 100 A (as per ratings)
- Charge voltage absorption
- 28.5 V
- Absorption time
- 1 – 2 hours
- Charge voltage float
- 26.5 V
- Temperature sensor
- Optional
- DC voltage compensation
- Optional
- Full load consumption
- As per ratings
- Current control function
- Yes
- Temperature range
- 0 – 55 °C
- Cooling
- Forced air cooling
- Protection degree
- IP 23
- Protections
- Over voltage, over current, over load, over temperature, short circuit
01Why SMEC?
- Fully automatic three stage charge characteristic
- Suitable for different battery types
- Protection against short circuit, overload and high temperature
- Forced air cooling for harsh environments
- LED display and read-out
- Galvanic isolation
02Engineering detail
Engineering detail
Technical scope / product architecture
- Charger and DC distribution
- Battery-bank interfaces
- Redundancy as specified
- AC input and protection
- Alarm/SCADA contacts
- Enclosure and environmental requirements
- FAT and commissioning
What SMEC adds
Engineering, interface definition, panel/package build, software/configuration where applicable, FAT, site installation support, SAT/commissioning and lifecycle support.
03More from the range
Other SMEC systems
Every system is built to the rig it serves and integrated with the rest of the installation.
Power HousesPCR House | SCR House | VFD HouseKnow More
Advanced Perimeter Security SystemSecure Your Boundaries with SMEC's Advanced Perimeter Security System!Know More
Drill Monitor SystemStay Alert, Stay Safe: Gas Watch Panel by SMECKnow More
Integrated Drilling Control SystemElevate Your Drilling: Precision Meets Innovation with SMEC’s Integrated Control System!Know More
Common questions
Can Industrial Battery Chargers & DC Systems be supplied for new build, retrofit or replacement?
The lifecycle route depends on the installed base, condition, interfaces, obsolescence and project requirements. SMEC can assess new-build, retrofit, repair or replacement scope where technically valid.
Can existing field wiring or interfaces be retained?
Possibly. Retention depends on survey findings, condition, ratings, compatibility, safety requirements, documentation and the cutover strategy.
What information is required for quotation?
Send the make/model or required specification, datasheets, drawings, ratings, interfaces, fault details where applicable, site location and required date or shutdown/mobilization window.
Related pages
Send the requirement
Send the available drawings, specification, make and model, site and required date. An engineer reviews the scope and replies.